K- 07 45 01 18

Base ejector Typ SBP
Pneumatic connection
8 mm 
Nozzle size
Vacuum port
10 mm 
PDF-faili allalaadimine
Detailne teave toote kohta

K- 07 45 01 18

Pneumatic connection
8 mm
Nozzle size
3
Vacuum port
10 mm
Air consumption suction
311 l/min
Dimension
168 mm x 20 mm x 46 mm
Max. suction capacity
215 l/min
Kõik omadused

Omadused

Silencer
  • plastic 
Application
  • for universal use in lightweight gripper systems 
  • to handle air-tight work pieces as well as for automatic separation systems 
  • e. g. in the plastics, electronics and packaging industries 
  • ideal for the construction of ejector blocks for decentralised control of suction pads 
Connector
  • Push-in connector 
Degree of evacuation
  • 85 %
Features
  • vacuum generator without control valves or system monitoring functions, with a high maximum vacuum value (85%) 
  • no moving parts, which means no wear and no maintenance 
  • max. suction capacity with minimum compressed air consumption 
  • minimum size, low weight 
  • for decentralised vacuum generation in highly dynamic processes 
Housing
  • plastic (durable) 
Max. working pressure
  • 4.5 bar 
Customs tariff number
  • 84141089 
Kõik omadused

Tootekirjeldus

Märkused
Further information on request.
Kirjeldus
Purely pneumatic vacuum generator that operates on the Venturi principle. Purely pneumatic vacuum generator that operates on the Venturi principle. Compressed air enters the ejector at A and flows through the nozzle B. This results in a vacuum immediately behind the nozzle outlet, and air is drawn in through the vacuum inlet D. This air and the driving air leave the ejector via the silencer C.

Product variants

6 Results
Mõõtmejoonis
Nimetus
Pneumatic connection
Nozzle size
Vacuum port
Air consumption suction (l/min)
4 mm 
4 mm 
14 l/min
Lisateave
4 mm 
4 mm 
22 l/min
Lisateave
6 mm 
8 mm 
48 l/min
Lisateave
6 mm 
8 mm 
105 l/min
Lisateave
8 mm 
10 mm 
197 l/min
Lisateave
8 mm 
10 mm 
311 l/min
Lisateave

Column selection

Pneumatic connection
Nozzle size
Vacuum port
Air consumption suction (l/min)
Degree of evacuation (%)
Dimension
Max. suction capacity (l/min)