HK PAM 190 P IO

Prop.-Leistungssteckerverstärker IO-Link
Rakendamine
Control of 1 proportional solenoid, with IO-Link interface (min. cycle time 4 ms, sampling time setpoint 1 ms). 
Elektriühendus
5-PIN-socket, M 12 
PDF-faili allalaadimine

Palun valige versioon

Kuva artiklitabel
Detailne teave toote kohta

HK PAM 190 P IO

Rakendamine
Control of 1 proportional solenoid, with IO-Link interface (min. cycle time 4 ms, sampling time setpoint 1 ms).
Elektriühendus
5-PIN-socket, M 12

Omadused

Rakendamine
  • universeller Leistungssteckerverstärker für Wegeventile 
Kasutamine
  • Universal for all common single and double solenoid proportional valves without transducer up to 24 V DC and max. 2.5 A 
Kaitse tüüp
  • IP 65 
Tööpinge
  • 24 V DC 
Töötemperatuur max.
  • 60 °C
Voolutugevus
  • bis 2,5 A 
Customs tariff number
  • 85423990 
Kõik omadused

Tootekirjeldus

Kirjeldus
This power amplifier offers various functions such as general valve adjustment, ramps, linearisation, dither frequency, dither amplitude, PWM frequency.
Tarnemaht
The scope of delivery includes the plug without connection cable.
Interface cable and any other parts required must be ordered separately.

Product variants

1 Result
Mõõtmejoonis
Nimetus
Interface
Kere
Rakendamine
Elektriühendus
Üksikasjad / items
IO-Link 
Hirschmann GDME DIN EN 175 301-803-A 
Control of 1 proportional solenoid, with IO-Link interface (min. cycle time 4 ms, sampling time setpoint 1 ms). 
5-PIN-socket, M 12 
Lisateave

Column selection

Interface
Kere
Rakendamine
Elektriühendus