What are you looking for?

Enter search term

We are sorry!

Unfortunately no results were found.

Login

Are you a new customer?

Register and get many benefits:

Checking the product availability
Fast reordering & order history
Personal product recommendation
Payment by invoice

Help & Contact

Your direct line to us

If you have any questions about the online store or our products, you can call our customer service at:

Monday - Thursday: 8:00AM - 5:00PM
Friday: 8:00AM - 4:00PM
Except saturdays, sundays and holidays

Or use our FAQ

There you get answers to the most frequently asked questions.

Helping people help themselves
FAQs

HK 92RV 04 B 41

Gear flow divider 4 4 sec. 4 valves
p1 max.
210 bar
p2 max.
260 bar
Flow per element min.
4.8 l/min
Download PDF
Product details for

HK 92RV 04 B 41

p1 max.
210 bar
p2 max.
260 bar
Flow per element min.
4.8 l/min
Flow per element rec'd
7.6 l/min
Flow per element max.
10 l/min
Input volume per section
4 cm³
A
47 mm
Li
444 mm
All characteristics

Characteristics

Design
  • with one phase compensation valve and anti-cavitation valve per section 
  • external leak oil discharge 
  • adjustment range DBV: 70 - 210 bar 
Pressure difference
  • max. 30 bar (between the sections) 
Construction type
  • 4 sections 
Size
  • group 2 
Customs tariff number
  • 84122981 
All characteristics

Product description

Notes
Before commissioning the system, the first running-in of the gear flow divider should be under no load.
Diagrams and circuit diagrams essentially valid as schematic diagrams also for 4-way flow dividers.
Description
This flow divider is used to supply four independent hydraulic circuits with just one pump.
Division error approx. 3 %.
Different pressure settings for each section possible.
Valves adjustable from 70 - 210 bar, other setting ranges on request.
Modification to internal leak oil discharge possible - for this, close off port T with G1/2″ blind plug (modification recommended only after consultation!).
After conversion to internal leak oil discharge, the function of the suction valves is disabled.
Configuration of gear flow dividers: qi = Q/z * 1000/n.
Qi = displacement/section [cm³].
Q = total input volume flow [l/min].
Z = number of sections.
N = rotating speed [rpm].
Further information
Recommended speed: 1800 - 2000 rpm

Product variants

5 Results
Show dimensional drawing
Identifier
p1 max. (bar)
p2 max. (bar)
Flow per element min. (l/min)
Flow per element rec'd (l/min)
Details / items
210 bar
260 bar
4.8 l/min
7.6 l/min
Learn more
210 bar
260 bar
7.2 l/min
10.8 l/min
Learn more
210 bar
260 bar
10.8 l/min
15.1 l/min
Learn more
210 bar
260 bar
13.2 l/min
19.4 l/min
Learn more
200 bar
230 bar
16.8 l/min
25.9 l/min
Learn more
p1 = max. working pressure
p2 = max. peak pressure

Column selection

p1 max. (bar)
p2 max. (bar)
Flow per element min. (l/min)
Flow per element rec'd (l/min)
Flow per element max. (l/min)
Input volume per section (cm³)
A (mm)
Li (mm)
p1 = max. working pressure
p2 = max. peak pressure